Full Description
Preface
This is the first edition of the User guide to AAMA/WDMA/CSA 101/I.S.2/A440, NAFS - North American Fenestration Standard/Specification for windows, doors, and skylights. It is jointly published by the American Architectural Manufacturers Association (AAMA), the Window (b) vehicular-access doors (garage doors) (See ANSI/DASMA 105, ANSI/DASMA 108, ANSI/DASMA 109, ANSI/DASMA 115, or other applicable DASMA Specifications); (c) roof-mounted smoke and heat-relief vents; (d) sloped glazing (other than unit skylights or roof windows) (See AAMA TIR A7); (e) curtain walls and storefronts (See AAMA MCWM-1); (f) folding door systems; (g) commercial entrance systems (See AAMA SFM-1); (h) sunrooms (See AAMA/NPEA/NSA 2100); (i) revolving doors; and (j) commercial steel doors rated per SDI A250.8. The reference Standards and technical publications specified in NAFS Clause 1.1 for products not within the scope of NAFS are for the convenience of the reader and are not intended to be considered complete or all-inclusive. These products are excluded for a variety of reasons, such as: no demonstrated need, lack of standardization or representation, redundancy with other standards, etc. 1.2 Terminology In NAFS, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with NAFS; "should" is used to express a recommendation or that which is advised but not required; "shall be permitted to be" is used to express an option or that which is permissible within the limits of NAFS; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and are written as requirements. Legends to equations and figures are considered requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.3 Units of measurement The values given in SI (metric) units are the standard. The values given in parentheses are for information only. The values given in parentheses are in IP (inch-pound) units and are often inexact rounded values. Users of NAFS will test only to the SI values or to exact conversions of the SI values. See CAN/CSA-Z234.1 or IEEE/ASTM SI 10 for conversion factors and rounding procedures that should be used in connection with testing. It is the policy of AAMA, CSA Group, and WDMA that all Standards developed by the associations use SI primary units, with IP units furnished for reference as necessary. This is consistent with Canadian and U.S. regulations for standardization of measurements. "In 1998 the Metric Conversion Act was amended to designate "the metric system of measurement as the preferred system of weights and measures for United States trade and commerce". With the increasing importance of the global marketplace, it has become imperative for U.S. industry to extend its use of SI and for U.S. citizens to gain a working knowledge of this modern metric system" (IEEE/ASTM SI 10). SI has been the official measurement system for Canada for a long time. It therefore makes sense that the primary units of measurement in NAFS are SI. The proper use of SI values and the conversion of SI values to IP values are outlined in CSA Z234.1 and IEEE/ASTM SI 10. These guidelines address both the base conversion of units but also the precision of the conversion. This process is not complicated for values that do not have limits such as maximums, minimums, and tolerances. However, in NAFS some requirements do require such limits. The values shown in NAFS have been converted according to the rules of the two referenced Standards. The conversions have sometimes been modified to meet the needs of expressing maximums, minimums, and tolerances. Consequently, NAFS users are advised that if they use the IP units provided for reference purposes, the onus is on them to determine the accuracy and appropriateness of the IP values for compliance with NAFS. The single exception to using SI values in NAFS is in the Performance Grade (PG) portion of the product designation. Here the nominal Performance Grades (PG) have been maintained as they were originally developed when the primary units of the predecessors to NAFS were in the IP system. This has been done as a convenience reflecting the acceptance of these nominal rating values in the architectural marketplace. The requirements for developing and specifying Performance Grades (PG) are provided as required in the body of NAFS. In all other instances the units of measurement and compliance are SI.