IEC 61094-8 Ed. 1.0 b:2012
Measurement microphones - Part 8: Methods for determining the free-field sensitivity of working standard microphones by comparison
standard by International Electrotechnical Commission, 09/19/2012
IEC 61094-8:2012 applicable to working standard microphones meeting the requirements of IEC 61094-4. It describes methods of determining the free-field sensitivity by comparison with a laboratory standard microphone or working standard microphone (where applicable) that has been calibrated according to either; IEC 61094-3; IEC 61094-2; IEC 61094-5; IEC 61094-6; or this part of IEC 61094. Methods performed in an acoustical environment that is a good approximation to an ideal free-field (e.g. a high quality free-field chamber), and methods that use post processing of results to minimise the effect of imperfections in the acoustical environment, to simulate free-field conditions, are both covered by this part of IEC 61094. Comparison methods based on the principles described in IEC 61094-3 are also possible but beyond the scope of this part of IEC 61094.
Product Details
Edition: 1.0 Published: 09/19/2012 Number of Pages: 61 File Size: 1 file , 620 KB