This document specifies:a) A multi-pass filtration performance test under cyclic flow conditions with continuous contaminant injection for hydraulic fluid power filter elements.b) A procedure for determining the contaminant capacity, particulate removal and differential pressure characteristics.c) A test currently applicable to hydraulic fluid power filter elements that exhibit an average filtration ratio greater than or equal to 75 for particle sizes ≤25 μm(c), and a final test system reservoir gravimetric level of less than 200 mg/L. It is necessary to determine by validation the range of flow rates and the lower particle size limit that can be used in test facilities.d) A test using ISO 12103-1 A3 medium test dust contaminant and a test fluid.This document provides a test procedure that yields reproducible test data for appraising the filtration performance of a hydraulic fluid power filter element without influence of electrostatic charge.This document is applicable to three test conditions:— Base upstream gravimetric level of 3 mg/L; — Base upstream gravimetric level of 10 mg/L; — Base upstream gravimetric level of 15 mg/L.
Product Details
Published: 11/30/2022 File Size: 1 file , 2.4 MB Note: This product is unavailable in Ukraine, Russia, Belarus