Full Description
              This Practice provides requirements for design and manufacture of horizontal centrifugal pumps of 150 kW (200 HP) or greater used for general water services. 
Comment: General water services include condensate, cooling water, demineralized water, utility water, produced water, treated water, etc. 
This Practice covers pumps with service conditions within the following limits: 
a. Maximum discharge pressure 35 Barg (500 psig) 
b. Minimum pumping temperature 0C (32F) 
c. Maximum pumping temperature 150C (300F) 
d. Maximum rotational speed 3,600 rpm 
Comment: For services within the capabilities of ANSI/ASME pumps, use PIP RESP73H. 
 Pump types covered by this Practice are broadly classified as overhung or between-bearings. The following pump types are not included in the scope of this Practice: 
a. Close coupled (i.e., impeller mounted on the motor shaft) 
b. Two-stage overhung 
c. Double suction overhung 