UL 60079-2

UL 60079-2 Explosive Atmospheres - Part 1: Equipment Protection by Pressurized Enclosure "p"

standard by Underwriters Laboratories, 06/02/2017

More details

Reduced price!
M00001554
New product
Limited time offer:

$87.75

$585.00

-85%

In stock

- +

Add to compare

 
More info

Full Description

Explosive Atmospheres - Part 2: Equipment Protection by Pressurized Enclosure "p"
UL 60079-2
1 Scope

This part of IEC 60079 standard contains the specific requirements for the construction and testing of electrical apparatus with pressurized enclosures, of type of protection "p", intended for use in explosive gas atmospheres hazardous (classified) locations defined as Class I, Zone 1 or Zone 2 by the National Electrical Code (NEC), ANSI/NFPA 70. It specifies requirements for pressurized enclosures containing a limited release of a flammable substance.

This standard supplements and modifies the general requirements of IEC ANSI/ISA-60079-0.Where a requirement of this standard conflicts with a requirement of IEC ANSI/ISA-60079-0, therequirements of this standard takes precedence.

This standard does not contain the requirements for:pressurized enclosures where the containment system may release
a) air with an oxygen content greater than normal, or
b) oxygen in combination with inert gas in a proportion greater than 21 %;pressurized rooms or analyser houses; see IEC 60079-13 and IEC 60079-16.NOTE 1 Due to the safety factors incorporated in the type of protection, the uncertainty of measurement inherent in good quality, regularly calibrated measurement equipment is considered to have no significant detrimental effect and need not be taken into account when making the measurements necessary to verify compliance of the equipment with the requirements of this standard.

NOTE 2 When the user acts in the role of the manufacturer, it is typically the user's responsibility to ensure that allrelevant parts of this standard are applied to the manufacturing and testing of the equipment.

NOTE 3 Types of protection "px" and "py" provide Equipment Protection Levels (EPL) Mb or Gb. Type of protection "pz" provides Equipment Protection Level (EPL) Gc. For further information, see Annex H.

 
Custom tab

This is a custom block edited from admin panel.You can insert any content here.

30 other products in the same category:

Compare 0
AS A14-1948                        [ Superseded ] 1xAS A14-1948... $62.55
AS CK5-1948                        [ Superseded ] 1xAS CK5-1948... $62.55
FORD W-HT1-14 1xFORD W-HT1-14 $15.75
AS O16-1948                        [ Superseded ] 1xAS O16-1948... $62.55
UL Subject 1564 1xUL Subject 1564 $74.85
ISO 14638:2015 1xISO 14638:2015 $46.35
UL 340 1xUL 340 $75.30
FORD W-GT1 1xFORD W-GT1 $15.75
ISO 13405-2:2015 1xISO 13405-2:2015 $46.35
ISO 14644-1:2015 Plus Redline 1xISO 14644-1:2015 Plus... $100.35
FORD W-GT2 1xFORD W-GT2 $15.75
BS 8459:2005 1xBS 8459:2005 $62.87
FORD W-GT3 1xFORD W-GT3 $15.75
ISO 17308:2015 1xISO 17308:2015 $20.25
BS 05/30133060 DC 1xBS 05/30133060 DC $67.50
UL 583 CRD 1xUL 583 CRD $74.85
AS O24-1948                        [ Superseded ] 1xAS O24-1948... $62.55
UL 83 1xUL 83 $134.55
UL 330 1xUL 330 $134.55
UL 4730 1xUL 4730 $75.30
ISO 14644-2:2015 Plus Redline 1xISO 14644-2:2015 Plus... $56.25
AS O20-1948                        [ Superseded ] 1xAS O20-1948... $62.55

No products

To be determined Shipping
$1,345.07 Total

Check out